JS-201A 60A Latching Relay For Intelligent Electric Meter

JS-201A 60A Latching Relay For Intelligent Electric Meter
Product Detailed
Related Categories:Relays
Small volume & PCB installation Low power consumption & strong load capacity Security, reliable and long working life

JS-201A 60A Latching Relay For Intelligent Electric Meter  

Description:

Latching relay is a new type of relay which uses magnetic principle to control circuit’s on and off. Its normally open and closed state are provided completely by permanent magnet steel’ working and completed the conversion of on-off state base on the triggering of a certain width pulse signal.

Product Properties:

1.Small volume, big switching power and low consumption

2.Coil instantaneous pulse driving and without fever

3.Stable permanent magnet force and save energy

4.High contact pressure, low contact resistance, working stable and reliable, anti-vibration and anti-shock.

5.Use manganin welding, low material temperature coefficient and compact structure.

Latching relay advantages:

(1)only need pulse excitation and can be single or double coils working

(2)small volume and PCB installation

(3)low power consumption and strong load capacity

(4)security, reliable and long working life

The effect of magnetic latching relay:

1.Expand control range. For example, when Multi- contact relay control signal reaches a certain value, it can simultaneously switch, disconnect and connect multiplex circuits according to the different forms of contact groups.

2.Enlarge. Such as sensitive relay, intermediate relay etc, it can control big power circuit with a very small control signal.

3.Integrated Signal. For example, when many control signals input multi-winding relay per required form, after comparing and integrating it can reach the intended control effect.

4.Automatic, remote control, monitor. For example, other relays and relay of automatic device can make up programs to control circuit, then reaching automatic operating.

Contact Specification:

Dimensions(mm)

38.5×33×17.2

Contact Form

1A/1B

Contact Material

Silver Alloy

Max Switching Current(Anti-load)

60A,80A

Max Switching Voltage

110VDC/250VAC

Max Switching Power

2400W/20000VA

Wight (without accessories)

45g

Coil Specification (20°C):

Rated Coil Voltage

6VDC

9VDC

12VDC

24VDC

48VDC

Coil Resistance

Single Coil(±10%Ω)

36

81

144

576

2304

Double Coil±10%Ω)

18

40.5

72

288

1152

Pick-up Voltage

≤75% Rated Coil Voltage

Drop-out Voltage

≤75% Rated Coil Voltage

Over-load Voltage

 ≤120% Rated Coil Voltage

Pick-up Time (At Rated Voltage)

≤20ms

Drop-out Time (At Rated Voltage)

≤20ms

Bounce Time

≤2ms

Power Consumption

Single coil: 1W;Double coil: 2W(special power consumption needs customize)

Characteristics:

Ambient Temp

-40~+70°C

Anti-vibration

10~55Hz,0.5mm (Double Amplitude)

Anti-shock

98m/s2,11ms

R.H.

45%~85%

Contact Resistance

≤2.0mΩ (1A/6VDC test)

Insulation Resistance

1000MΩ (500VDC)

Dielectric voltage-withstand

Between Contacts

1800 VAC 50/60Hz (1 Minute)

Between Contact and Coil

4000 VAC 50/60Hz (1 Minute)

Life

Electrical Life

≥1*104OPS

Mechanical Life

≥1*105OPS

Application:

Widely used in Prepaid energy meter, meter reading system, composite switch, reactive power compensation device and automatic control equipments etc.

Notes:

1.Relay is on the "reset" or "set" status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to "set" or "reset" status, therefore, when application (connecting the power supply),please reset the relay to "set" or "reset" status on request.

2.In order to maintain "set" or "reset" status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than "set" or "reset" time. Do not energize voltage to "set" coil and "reset" coil simultaneously. And also long energized time(more than 1 min) should be avoided.

3.In order to avoid changing operate voltage, products should not be kept in strong magnetic field during transportation, storage and application.

4. Sampling resistance: 100-1200μΩ